This flashing is typically field fabricated from a sheet of 26 ga.
Headwall flashing with siding.
The flashing extends up the wall at least 4 the flashing extends onto the roof a minimum of 2 inches 4 inches is preferable in more severe climate areas.
A headwall is defined by the junction between a sloped roof and a wall.
This has proven problematic over time as caulking the joint results in unsightly surface appearances due to the different textures as well as resulted.
In the last picture you can see they caulked between the wood shingle siding joints suggesting they had water damage inside below that are confirmed by old.
The flashing needs to be installed before installing the roof shingles.
Don t mistake this condition for headwall flashing routed beneath the shingles and call it a defect.
A common problem with cement board siding products and some other types of horizontal lap siding is that older installation guidelines called for caulking the joint instead of flashing the joint.
Posted march 4 2017 filed under roof installation roof repair maintenance.
Flashing should overlap the roof covering material but on asphalt shingle roofs for aesthetic reasons the part of the headwall flashing that extends down over asphalt shingles is often covered with a course of shingle tabs.
Step flashing is used to provide a water tight connection where roofing adjoins a vertical juncture.
Unless already installed a water resistive barrier should be applied to the house prior to installing vinyl siding.
Consult your local building code for requirements in your geographic area.
Install flashing before starting to apply the siding.
Bent into an l shape.
On metal roofing systems a headwall flashing is designed to hook on the j channel or z channel and extend up behind the wall exterior while in shingle and slate roof the headwall sits on the first.
Galvanized sheet metal bent at a 90 degree angle i e.
The headwall flashing in the 2nd pic however seems like it s not going to work since it is outside the siding and it doesn t appear there is any sealant at the top of it.
Flashing this area of a roof correctly is very important to avoid leaks.
The metal flashing is formed with a hook edge and cleated on 12 centers.
Refer to important notes for more information on water resistive barriers.